| NX-200 | NX-300 | ||
|---|---|---|---|
| GENERAL | |||
| Frequency Range | Type 1 | 136-174 MHz | 450-520 MHz |
| Type 2 | 400-470 MHz | ||
| Number of Channels | 512 | ||
| Zones | 128 | ||
| Max. Channels per Zone | 250 | ||
| Channel Spacing | Analog | 12.5 / 15 / 25 / 30 kHz | 12.5 / 25 kHz |
| Digital | 6.25 / 12.5 kHz | 6.25 / 12.5 kHz | |
| Operating Voltage | 7.5V DC ± 20% | ||
| Battery Life (with KNB-48L) | 5-5-90 | More than 14.5 hours | |
| 10-10-80 | More than 9.0 hours | ||
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F) | ||
| Frequency Stability | ± 2.0 ppm | ± 1.0 ppm | |
| Antenna Impedance | 50 Ω | ||
| Dimensions (W x H x D) Projections not included | Radio only | 58 x 127.5 x 41.3 mm | |
| with KNB-47L | 58 x 127.5 x 41.3 mm | ||
| with KNB-48L | 58 x 127.5 x 48.5 mm | ||
| Weight (net) | Radio only | 260 g | |
| with KNB-47L | 375 g | ||
| with KNB-48L | 405 g | ||
| RECEIVER | |||
| Sensitivity | Digital @ 6.25kHz (3% BER) | 0.20 μV | |
| Digital @ 12.5kHz (3% BER) | 0.25 μV | ||
| Analog (12 dB SINAD) | 0.25 μV | ||
| Selectivity | Analog @ 25 kHz | 72 dB | |
| Analog @ 12.5 kHz | 65 dB | ||
| Intermodulation Distortion | Analog | 70 dB (±50,100 kHz) | |
| Spurious Response | Analog | 70 dB | |
| Audio Distortion | Less than 3% | ||
| Audio Output | 500 mW / 8 Ω | ||
| TRANSMITTER | |||
| RF Power Output | 5 W / 1 W | ||
| Spurious Response | 70 dB | ||
| FM Hum & Noise | Analog @ 25 kHz | 45 dB | |
| Analog @ 12.5 kHz | 40 dB | ||
| Audio Distortion | Less than 3% | ||
| Modulation | 16K0F3E, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D |
||
Analog measurements made per TIA/EIA 603 and specifications shown are typical.
Specifications are subject to change without notice, due to advancements in technology.
FleetSync® is a registered trademark of JVC KENWOOD Corporation.
LTR® is a registered trademark of Transcrypt International.
AMBE+2™ is a trademark of Digital Voice Systems Inc.
Windows® is a registered trademark of Microsoft Corporation.
NXDN® is a registered trademark of JVC KENWOOD Corporation and Icom Inc.
NEXEDGE® is a registered trademark of JVC KENWOOD Corporation in U.S.A. and some countries.
| MIL Standard | MIL 810C Methods/ Procedures |
MIL 810D Methods/ Procedures |
MIL 810E Methods/ Procedures |
MIL 810F Methods/ Procedures |
MIL 810G Methods/ Procedures |
|---|---|---|---|---|---|
| Low Pressure | 500.1/ Procedure I |
500.2/ Procedure I, II |
500.3/ Procedure I, II |
500.4/ Procedure I, II |
500.5/ Procedure I, II |
| High Temperature | 501.1/ Procedure I, II |
501.2/ Procedure I, II |
501.3/ Procedure I, II |
501.4/ Procedure I, II |
501.5/ Procedure I, II |
| Low Temperature | 502.1/ Procedure I |
502.2/ Procedure I, II |
502.3/ Procedure I, II |
502.4/ Procedure I, II |
502.5/ Procedure I, II |
| Temperature Shock | 503.1/ Procedure I |
503.2/ Procedure I |
503.3/ Procedure I |
503.4/ Procedure I, II |
503.5/ Procedure I |
| Solar Radiation | 505.1/ Procedure I |
505.2/ Procedure I |
505.3/ Procedure I |
505.4/ Procedure I |
505.5/ Procedure I |
| Rain | 506.1/ Procedure I, II |
506.2/ Procedure I, II |
506.3/ Procedure I, II |
506.4/ Procedure I, III |
506.5/ Procedure I, III |
| Humidity | 507.1/ Procedure I, II |
507.2/ Procedure II, III |
507.3/ Procedure II, III |
507.4 | 507.5/ Procedure II |
| Salt Fog | 509.1/ Procedure I |
509.2/ Procedure I |
509.3/ Procedure I |
509.4 | 509.5 |
| Dust | 510.1/ Procedure I |
510.2/ Procedure I |
510.3/ Procedure I |
510.4/ Procedure I, III |
510.5/ Procedure I |
| Vibration | 514.2/ Procedure VIII, X |
514.3/ Procedure I |
514.4/ Procedure I |
514.5/ Procedure I |
514.6/ Procedure I |
| Shock | 516.2/ Procedure I, II, V |
516.3/ Procedure I, IV |
516.4/ Procedure I, IV |
516.5/ Procedure I, IV |
516.6/ Procedure I, IV |
| International Protection Standard | |||||
| Dust & Water Protection | IP54/55 | ||||