NX-200s/300s

  NX-200S NX-300S
GENERAL
Frequency Range 136 ~ 174 MHz 400 ~ 470 MHz
Number of Channels 64
Zones 4
Max. Channels per Zone 16
Channel spacing
Analogue
Digital
 
12.5 / 20 / 25 kHz
6.25 / 12.5 kHz
Operating Voltage 7.5 V DC ± 20%
Battery life (with KNB-48L)
5-5-90
10-10-80
 
More than 14.5 hours
More than 9.0 hours
Operating Temperature Range -30°C to +60°C
Frequency Stability ±2.0 ppm ±1.0 ppm
Antenna impedance 50 Ω
Dimensions (W x H x D),
Projections not included
Radio Only
with KNB-47L
with KNB-48L
 
 
58 x 128.3 x 41.7 mm
58 x 128.3 x 41.7 mm
58 x 128.3 x 49.1 mm
Weight (net)
Radio Only
with KNB-47L
with KNB-48L
 
255 g
370 g
400 g
Applicable Standards
ETSI R & TTE
 
ETSI Safety
 
EN 300 086, EN 300 113, EN 300 219,
EN 301 489, EN 301 166
EN 60065, EN 60950-1, EN 60215
RECEIVER
Sensitivity (Analogue)
EIA 12dB SINAD
(25kHz / 20kHz / 12.5kHz)
EN 20dB SINAD
 
0.28 µV / 0.28 µV / 0.32 µV
 
-3 dB µV (0.35 µV) / -3 dB µV (0.35 µV) / -1 dB µV (0.45 µV)
Sensitivity (Digital)
3% BER
(12.5kHz / 6.25kHz)
1% BER
 
0.32 µV / 0.25 µV
 
-1 dB µV (0.45 µV) / -4 dB µV (0.32 µV)
Adjacent Channel Selectivity (Analogue)
(25kHz / 20kHz / 12.5kHz)
 
76 dB / 74 dB / 68 dB
Intermodulation (Analogue) 65 dB
Spurious Response Rejection (Analogue) 75 dB
Audio Distortion Less than 3%
Audio Output 500 mW / 8 Ω
TRANSMITTER
RF Power Output
High / Low
 
5 W / 1 W
Modulation Limiting (Analogue) ± 5.0 kHz at 25 kHz
± 4.0 kHz at 20 kHz
± 2.5 kHz at 12.5 kHz
Spurious Emission - 36 dBm <= 1 GHz, -30 dBm > 1 GHz
FM Noise (EIA)
(Analogue, 25 kHz / 20 kHz / 12.5 kHz)
 
45 dB / 45 dB / 40 dB
Modulation Distortion Less than 3%
Microphone Impedance 1.8 kΩ
Modulation 16K0F3E, 14K0F3E, 14K0F2D, 12K0F2D, 8K50F3E, 7K50F2D, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D

FleetSync® is a registered trademark of KENWOOD Corporation.
LTR® is a registered trademark of Transcrypt International.
AMBE+2TM is a trademark of Digital Voice Systems Inc.
Windows® is a registered trademark of Microsoft Corporation.
NXDN® is a registered trademark of KENWOOD Corporation and Icom Inc.
NEXEDGE® is a registered trademark of KENWOOD Corporation in Japan, Australia, Singapore and some other countries.

Analogue measurements made per EN Standards or TIA/EIA 603 and specifications shown are typical.
KENWOOD reserves the right to change specifications without prior notice or obligation.

Applicable MIL-STD & IP

MIL Standard MIL 810C
Methods/Procedures
MIL 810D
Methods/Procedures
MIL 810E
Methods/Procedures
MIL 810F
Methods/Procedures
Low Pressure 500.1/Procedure I 500.2/Procedure I, II 500.3/Procedure I, II 500.4/Procedure I, II
High Temperature 501.1/Procedure I, II 501.2/Procedure I, II 501.3/Procedure I, II 501.4/Procedure I, II
Low Temperature 502.1/Procedure I 502.2/Procedure I, II 502.3/Procedure I, II 502.4/Procedure I, II
Temperature Shock 503.1/Procedure I 503.2/Procedure I 503.3/Procedure I 503.4/Procedure I, II
Solar Radiation 505.1/Procedure I 505.2/Procedure I 505.3/Procedure I 505.4/Procedure I
Rain 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II 506.4/Procedure I, III
Humidity 507.1/Procedure I, II 507.2/Procedure II, III 507.3/Procedure II, III 507.4
Salt Fog 509.1/Procedure I 509.2/Procedure I 509.3/Procedure I 509.4
Dust 510.1/Procedure I 510.2/Procedure I 510.3/Procedure I 510.4/Procedure I, III
Vibration 514.2/Procedure VIII, X 514.3/Procedure I 514.4/Procedure I 514.5/Procedure I
Shock 516.2/Procedure I, II, V 516.3/Procedure I, IV 516.4/Procedure I, IV 516.5/Procedure I, IV
International Protection Standard
Dust & Water Protection IP54/55